When to notify status page subscribers (and when to stay quiet)

Subscribers trust a status page only if its emails are worth reading. Which events to notify on, how often to update, and wording rules that avoid noise.

· 6 min read · By the Spot Downtime team

A status page that updates is useful. A status page that emails its subscribers for every blip trains them to ignore it, and the one email that matters lands in a folder nobody reads. Notification policy is a design decision, not a default setting.

This post sets out which events deserve a notification, what to send and when, and how to write messages that people act on.

What subscribers actually want

Someone who subscribes to your status page wants three answers: is something wrong, does it affect me, and when will I hear more. Every notification should answer at least one of those. If it answers none, it should not be sent.

Events worth an email

  • An incident is confirmed and customer-visible. Send the first notice once you know users are affected, even if the cause is unknown. A short honest message beats waiting for a full explanation.
  • The impact changes materially. A partial outage becomes a full one, or a new feature is affected.
  • A workaround exists. If users can do something now, tell them.
  • The incident is resolved. Always send this one. Subscribers are waiting for it.
  • Planned maintenance is coming. One notice well ahead of time, and a reminder shortly before if the window is risky for users.

Events to keep on the page only

  • Routine progress updates such as "still investigating" with no new information. Post them on the page for people who are looking, but do not email everyone each time.
  • Internal-only problems that no customer can see: a failing staging environment, a delayed analytics job.
  • Brief blips. A one-minute failure that recovered by itself does not need a notification. A short note in the history is enough. If these are frequent, the better fix is fewer false alarms; see how to reduce false uptime alerts.

A rule of thumb

Notify when a reasonable customer would want to change what they are doing: stop retrying, switch to a workaround, warn their own users, or wait. Otherwise, update the page quietly.

How often to update during an incident

Pick a cadence when you post the first message and keep it, even when there is nothing new. "Next update in 30 minutes" is a commitment that lets people stop refreshing. If you have no news at that time, say so on the page. Silence is what makes subscribers assume the worst.

Not every cadence post needs an email. A good pattern is to email on the first notice, on a material change, on the resolution, and at long intervals if the incident drags on.

Writing the message

  • Lead with the impact in plain language: what users cannot do, not which service is failing.
  • Say what you know and what you do not. Do not guess at causes you have not confirmed.
  • State when the next update will come.
  • Skip internal names, ticket numbers and blame.
  • In the resolution message, say what was fixed and whether users need to do anything. A full write-up can follow later.

A first notice might read: "Some customers cannot log in. Logged-in sessions are not affected. We are investigating and will post another update within 30 minutes." It states impact, scope and timing, and nothing it cannot back up. For more examples, see incident status updates and the message to send customers when your website is down.

Keep the audience in mind

Subscribers have different needs. An API customer cares about a degraded endpoint that an end user never notices. If your page lists components separately, name the affected component in the title so people can judge relevance at a glance. See status page best practices for structuring a page.

Plans cap how many email subscribers a page can have, which is another reason to treat the list as something worth earning and keeping. The current limits for each plan are on the pricing page.

After the incident

Check how many people unsubscribed or marked the email as spam. If they leave after an incident, you probably sent too much or too vaguely. Adjust the rules above and review them in your post-incident review.

Checklist

  • Email on confirmed customer impact, material changes, workarounds and resolution.
  • Announce planned maintenance ahead of time, not at the start of the window.
  • Commit to an update cadence and keep it on the page, with emails only when there is news.
  • Write in terms of what users experience, with a time for the next update.
  • Review unsubscribes and complaints after each major incident.

Set up the page

Spot Downtime status pages are described under status pages, and how to set up a status page walks through creating one.

Downtime cost calculatorEstimate what an outage costs, to decide which incidents are worth a full notification.

Get new guides by email

Practical posts on monitoring, outages, error fixes and on-call, when they're published. No spam.

Unsubscribe from any email with one click. See our privacy policy.

Keep reading